Garador Sectional Garage Door Measuring Guide

GARADOR SECTIONAL GARAGE DOORS

Sectional Garage Door
Measuring Guide

Accurate measurements are essential when ordering your Garador Sectional garage door. This guide explains how to measure your garage opening, headroom, sideroom and internal garage depth before configuring your new door.

Important: measure the finished structural opening and the available space inside the garage. Sectional doors require space behind and above the opening for the tracks and lifting gear.
Opening Width
Opening Height
BEFORE YOU START

Measure the
Opening Carefully.

Garador Sectional garage doors are generally designed to fit behind the garage opening. This allows the door to rise vertically before travelling horizontally beneath the garage ceiling.

Because of this, the opening width and height are only part of the measurement process. You must also check the available sideroom, headroom and garage depth.

Measure in several positions wherever possible. Brickwork, render, floor levels and ceilings are not always perfectly square, so never rely on a single measurement.

STEP 01

Measure Your Garage Opening

Take all measurements in millimetres. Measure the opening itself first, followed by the available space around and behind it.

1

Opening Width

Measure the brick-to-brick opening width at the top, middle and bottom. Record the smallest measurement.

2

Opening Height

Measure from the finished floor level to the underside of the lintel at the left, centre and right. Record the smallest measurement.

3

Sideroom

Measure the clear wall space immediately behind the opening on both sides. Garador Sectional doors generally require at least 90 mm each side.

4

Headroom

Measure vertically from the underside of the lintel to the lowest obstruction above it, including beams, pipes, lights and ceiling structures.

A Width

Smallest brick-to-brick opening width.

B Height

Smallest floor-to-lintel opening height.

C Sideroom

Clear internal wall space on both sides.

D Headroom

Clear space above the garage opening.

STEP 02

Check Your Headroom

The required headroom depends on the Sectional spring and track arrangement selected for your door.

Track / Spring Arrangement Manual Door With GaraMatic Sideroom
Tension Z Spring
Common on smaller Sectional doors.
100 mm minimum headroom 115 mm minimum headroom 90 mm each side
Torsion N Spring
Standard on larger compatible doors.
210 mm minimum headroom 210 mm minimum headroom 90 mm each side
Low Headroom Torsion L Track
Used where headroom is restricted.
100 mm minimum headroom 115 mm minimum headroom 90 mm each side
Do you have restricted headroom?

Do not automatically choose a smaller door. Garador offers compatible low-headroom track arrangements for selected Sectional doors. Enter your measurements accurately in the configurator so the appropriate options can be identified.

STEP 03

Measure the Garage Depth

Sectional doors travel horizontally beneath the ceiling after opening, so sufficient clear space is required inside the garage.

Manual Door Door Height + 510 mm

Minimum internal depth for the standard manual Sectional track arrangement.

GaraMatic · up to 2125 mm high 3200 mm

Minimum garage depth for an automated door within this height range.

GaraMatic · up to 2500 mm high 3450 mm

Minimum garage depth typically required for the corresponding GaraMatic boom arrangement.

Check the entire ceiling area.

Measure to the nearest obstruction, not simply to the rear garage wall. Be aware of ceiling joists, lights, storage systems, loft hatches, pipework, beams and existing garage-door equipment.

STEP 04

Check the Floor & Opening

The garage floor and structural opening should be assessed before ordering, particularly where the building is older or has recently been altered.

✓
Finished floor level

Measure from the final floor surface, not from an unfinished slab that will later receive screed, tiles or another finish.

✓
Level threshold

Check whether the floor slopes significantly across the garage opening as this can affect the bottom weather seal.

✓
Solid fixing surfaces

Confirm that the reveals and lintel provide suitable structural fixing locations for the frame and tracks.

✓
Clear internal walls

Remove or account for pipes, cables, shelves and other items occupying the required sideroom.

✓
Clear ceiling

Make sure the horizontal tracks and GaraMatic operator have a clear route into the garage.

✓
Opening is square

Compare measurements at different positions and check the diagonals if the opening appears noticeably out of square.

IMPORTANT

Behind-the-Opening Installation

Garador Sectional garage doors are primarily designed to install behind the structural garage opening. This helps provide full drive-through width and allows the vertical tracks to sit behind the reveals.

Planning to install between the brickwork?

A different fixing arrangement may be required. Garador offers a special anchor set for suitable applications, and cover profiles may also be required. If your installation cannot sit behind the reveals, confirm the fitting arrangement before ordering.

YOUR MEASUREMENTS

Record Everything Before Ordering

Keep these measurements together while using the Red Oak Garador Sectional configurator.

Opening Width
Opening Height
Left Sideroom
Right Sideroom
Headroom
Clear Garage Depth
FINAL CHECK

Before You Configure Your Door

✓
Opening measured in three positions

Use the smallest reliable width and height measurements.

✓
At least 90 mm sideroom checked

Confirm this on both the left and right sides.

✓
Headroom checked

Account for the selected track and operation type.

✓
Garage depth checked

Ensure tracks and operator have sufficient internal clearance.

✓
Floor level checked

Use finished floor level for your final opening height.

✓
Obstructions checked

Check beams, pipework, lights, shelving and ceiling storage.

MEASUREMENTS READY?

Build Your Garador
Sectional Door.

Choose your Sectional design, size, surface finish, colour, glazing, operation and compatible GaraMatic options using our online configurator.

Configure Your Sectional Door →